GUIDE SPECIFICATION
Corporate Office:
Panel Brick Manufacturing, Inc.
P.O. Box 907
1120 Ewing Road
Owensboro, Kentucky 43202
270-684-7268 voice
http:/www.thinbrickbyOwensboro.com
SECTION 04840
THIN BRICK/PANEL BRICK VENEER
**************************************************************************************************************************************
Welcome to the Thin Brick/Panel Brick Guide Specification! Panel Brick Manufacturing, Inc. has prepared this guide specification in electronic media, as an aid to specifiers in preparing written construction documents for Section 04840 Thin Brick Brickettes © and Panel Brick Veneer.
The specifier can edit entire master to suit project requirements, modify or add items as necessary, or delete non-applicable items. Words and sentences within brackets [_____] reflect a choice to be made regarding inclusion or exclusion of a particular item or statement. This Section may include performance, proprietary, and descriptive type specifications. Edit to avoid conflicting requirements. Notes to guide the specifier are included between lines of asterisks to assist in choices to be made. They should be removed before the Section is printed for use.
This guide specification is based on the Construction Specifications Institute (CSI) Section Format standards. References to section names and numbers are based on MasterFormat 95 recommendations.
For specification assistance with specific product applications, please contact the offices above.
In the interest of continuous improvement of its product line, Panel Brick Manufacturing, Inc. reserves the right to modify its products composition, colors, textures, sizes, and other physical and performance attributes, and subsequently, these guide specifications at any time. Updates to this guide specification will be posted as they occur. Panel Brick Manufacturing, Inc. makes no expressed or implied warranties regarding content, errors, or omissions in the information presented. Specifications modified or rewritten to not be in conformance with manufacturers standard processes, products, and procedures, may void warranties and related remedies. **************************************************************************************************************************************
**************************************************************************************************************************************
Retain and edit following paragraph and related subparagraphs for Project as required, or delete if cross-referencing is not necessary for Project.
**************************************************************************************************************************************
**************************************************************************************************************************************
Retain following paragraph if Section is affected by Alternates defined for Project.
**************************************************************************************************************************************
**************************************************************************************************************************************
Include submittal requirements below, which are consistent with the scope of the project and extent of work of this Section. Only request submittals which are necessary for review of design intent.
**************************************************************************************************************************************
*************************************************************************************************************************************
Include quality assurance requirements below, which are consistent with the size and scope of the project and extent of work of this Section. Only request qualification statements which you intend to review, and which are necessary to establish qualifications of the product, manufacturer, or installer.
*************************************************************************************************************************************
*************************************************************************************************************************************
Retain applicable certification requirements, which are consistent with the Project and its location. Coordinate with thin brick veneer manufacturer.
*************************************************************************************************************************************
*************************************************************************************************************************************
Insert thin brick veneer color. Refer to thin brick veneer manufacturers current product literature.
*************************************************************************************************************************************
*************************************************************************************************************************************
Insert thin brick veneer special shape requirement below as required for specific project, selected from manufacturers standard product lines.
*************************************************************************************************************************************
*************************************************************************************************************************************
Insert thin brick veneer accessories below as required for specific project.
*************************************************************************************************************************************
*************************************************************************************************************************************
"Pigments" below are only needed for applications where the mortar joints will be exposed and a custom color is required for the joints.
*************************************************************************************************************************************
*************************************************************************************************************************************
Select one of the following two subparagraphs. Moisture barrier over sheathing is required by most codes. Option "a" is recommended by manufacturer as a positive means of stopping moisture migration through wall and diverting free moisture to base of wall. Option "b" is a less expensive product, yet still meets code requirements.
*************************************************************************************************************************************
*************************************************************************************************************************************
Moisture barrier is needed over sheathing substrates for exterior applications.
*************************************************************************************************************************************
*************************************************************************************************************************************
Select the appropriate installation for the construction from the options listed.
*************************************************************************************************************************************
*************************************************************************************************************************************
Select the appropriate construction from the options listed.
*************************************************************************************************************************************
END OF SECTION